Type MP6500 host, S2211T molded case pH three composite electrodes,
Type S3221 glass pH composite electrode, E2228T glass electrode conductance ( K=1, ATC ),
G1218 type dissolved oxygen electrode, T2132 temperature electrode,
R2323 type double liquid junction reference electrode, ST901 intelligent mixer, Universal electrode holder,
G1218- 1 type dissolved oxygen electrode diaphragm cap, pH standard buffer solution,
Conductivity correction solution, Dissolved oxygen electrode in G1218-3 solution,
USB communication cable, communication software CD and instrumentation suitcase.
Selective electrode
· S3221D glass pH composite electrode for high water -- pH measurement
· S2211F plane pH composite electrode -- for the solid or semi-solid moist surface of pH measurements, such as skin, paper, cloth, meat and fruit;
And colloidal solution and trace the solution pH measurement.
· E3228T type conductance electrode ( k=0.1, ATC ) -- used in high pure water conductivity measurement;
· E1218T type conductance electrode ( k=10, ATC ) -- for high concentration conductivity measurement;
Performance characteristics
· Ion measurement: There are ten kinds of common ions are available, and can also customize other ions.
· One to five point PH automatic correction, Conductivity of one to four automatic correction, Ion two to five automatic correction and automatically check function;
· PH 0 ~ 100.0 celsius degree automatic / manual temperature compensation; Ionic automatic / manual temperature compensation ( 0~60.0 ); Electrical conductivity ( 0~50.0 )celsius degree automatic / manual temperature compensation system;
· Ion unit can select and switch pX; Mol/L; Mg/L and ppm;
· High conductivity pure water conductivity measurement mode, choice of reference temperature; Electrode constant selection; Temperature compensation coefficient;
· Dissolved oxygen 0~45 celsius degree automatic temperature compensation; 0~45ppt automatic salinity compensation;
· 80~105kPa manual pressure compensation; Calibration set of water saturated air automatic correction;
· Stable data display mode;
· GLP-compliant data management, data storage 300 groups (manual and automatic storage); USB communication interface;
· PH standard solution selection ( China standard, Europe standard, NIS standard and custom );
· High pure water pH measurement mode and Ammonia water pH measurement mode;
· Temperature selectable units (celsius degree and fahrenheit);
· Restore factory settings; · 90 × 68mm large-screen LCD, large font display, clear, and easy to operate; · Meets IP54 waterproof rating. Jack has a rubber cap sealing protection apparatus.
· Configuration has a salinity compensation of dissolved oxygen electrode, electrode calibration sets of stirrer and intelligent;
Technical parameters
Type S3221 glass pH composite electrode, E2228T glass electrode conductance ( K=1, ATC ),
G1218 type dissolved oxygen electrode, T2132 temperature electrode,
R2323 type double liquid junction reference electrode, ST901 intelligent mixer, Universal electrode holder,
G1218- 1 type dissolved oxygen electrode diaphragm cap, pH standard buffer solution,
Conductivity correction solution, Dissolved oxygen electrode in G1218-3 solution,
USB communication cable, communication software CD and instrumentation suitcase.
Selective electrode
· S3221D glass pH composite electrode for high water -- pH measurement
· S2211F plane pH composite electrode -- for the solid or semi-solid moist surface of pH measurements, such as skin, paper, cloth, meat and fruit;
And colloidal solution and trace the solution pH measurement.
· E3228T type conductance electrode ( k=0.1, ATC ) -- used in high pure water conductivity measurement;
· E1218T type conductance electrode ( k=10, ATC ) -- for high concentration conductivity measurement;
Performance characteristics
· Ion measurement: There are ten kinds of common ions are available, and can also customize other ions.
· One to five point PH automatic correction, Conductivity of one to four automatic correction, Ion two to five automatic correction and automatically check function;
· PH 0 ~ 100.0 celsius degree automatic / manual temperature compensation; Ionic automatic / manual temperature compensation ( 0~60.0 ); Electrical conductivity ( 0~50.0 )celsius degree automatic / manual temperature compensation system;
· Ion unit can select and switch pX; Mol/L; Mg/L and ppm;
· High conductivity pure water conductivity measurement mode, choice of reference temperature; Electrode constant selection; Temperature compensation coefficient;
· Dissolved oxygen 0~45 celsius degree automatic temperature compensation; 0~45ppt automatic salinity compensation;
· 80~105kPa manual pressure compensation; Calibration set of water saturated air automatic correction;
· Stable data display mode;
· GLP-compliant data management, data storage 300 groups (manual and automatic storage); USB communication interface;
· PH standard solution selection ( China standard, Europe standard, NIS standard and custom );
· High pure water pH measurement mode and Ammonia water pH measurement mode;
· Temperature selectable units (celsius degree and fahrenheit);
· Restore factory settings; · 90 × 68mm large-screen LCD, large font display, clear, and easy to operate; · Meets IP54 waterproof rating. Jack has a rubber cap sealing protection apparatus.
· Configuration has a salinity compensation of dissolved oxygen electrode, electrode calibration sets of stirrer and intelligent;
Technical parameters
Measuring range | Ion concentration | 0.00~14.00 pX |
pH | (-2.000~19.999) pH | |
mV | -1999.9 mV ~ 0 ~ +1999.9mV | |
Cond | 0.00μS/cm~2000mS/cm includes: (0.00~20.00μS/cm)(20.0~200.0μS/cm)(200~2000μS/cm)(2.00~20.00mS/cm)(20.0~200.0mS/cm)(200~2000mS/cm) | |
Resistivity | (0~100)MΩ?cm | |
TDS | (0~100)g/L | |
Salinity | (0~100)ppt | |
Dissolved oxygen | (0~20.0)mg/L(ppm) | |
Dissolved oxygen saturation | (0.0~100.0)% | |
Temp | (-10~110)celsius degree | |
Resolution | Ion concentration | 0.01 pX,0.01mol/L,0.01mg/L,0.01ppm |
pH | 0.001 pH | |
mV | 0.1 mV | |
Cond | 0.01/0.1/1μS/cm;0.01/0.1/1mS/cm | |
Dissolved oxygen | 0.1 mg/L | |
Dissolved oxygen saturation | (0.0~100.0)% | |
Temp | 0.1celsius degree | |
Basic error | Ion concentration | ±0.01 pX()±0.02 pX() |
pH | ±0.002 pH | |
mV | ±0.03%FS | |
Cond | ±0.5%FS | |
Dissolved oxygen | ±0.3 mg/L | |
Temp | ±0.4celsius degree | |
Response time | 30s(25 celsius degree,90% response) | |
Residual current | 0.1 mg/L |